CVEvulnerability

CVE-2025-11781

8.6 HIGH Published 2025-12-02 Modified 2026-09-26 Official page ↗
Status
Analyzed
Published
2025-12-02
Last modified
2026-09-26
Assigner
[email protected]
CVSS 4.0 ([email protected])
8.6 HIGH — CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weaknesses
CWE-321

Description

Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges.

Affected configurations

• circutor sge-plc1000 firmware 9.0.2 • circutor sge-plc50 firmware 9.0.2

Related

Weakness · CWE (1)

  • CWE-321 Use of Hard-coded Cryptographic Key weakness

References