CVEvulnerability

CVE-2025-11789

7.1 HIGH Published 2025-12-02 Modified 2026-09-25 Official page ↗
Status
Analyzed
Published
2025-12-02
Last modified
2026-09-25
Assigner
[email protected]
CVSS 4.0 ([email protected])
7.1 HIGH — CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weaknesses
CWE-125

Description

Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'DownloadFile' function converts a parameter to an integer using 'atoi()' and then uses it as an index in the 'FilesDownload' array with '(&FilesDownload)[iVar2]'. If the parameter is too large, it will access memory beyond the limits.

Affected configurations

• circutor sge-plc1000 firmware 9.0.2 • circutor sge-plc50 firmware 9.0.2