CVEvulnerability

CVE-2025-13605

9.3 CRITICAL Published 2026-05-04 Modified 2026-10-07 Official page ↗
Status
Awaiting Analysis
Published
2026-05-04
Last modified
2026-10-07
Assigner
[email protected]
CVSS 4.0 ([email protected])
9.3 CRITICAL — CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weaknesses
CWE-78

Description

3onedata modbus gateway device model GW1101-1D(RS-485)-TB-P (hardware version V2.2.0) allows authenticated users to execute arbitrary shell commands in the context of the root user by providing payload in the "IP address" field of the diagnosis test tools. This issue has been resolved in firmware version 3.0.59B2024080600R4353

Related

Weakness · CWE (1)

  • CWE-78 Improper Neutralization of Special Elements used in an OS Command weakness

References