CVEvulnerability
CVE-2025-23402
7.3 HIGH
Official page ↗
- Status
- Analyzed
- Published
- 2025-03-11
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 4.0 ([email protected])
- 7.3 HIGH — CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- CVSS 3.1 ([email protected])
- 7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Weaknesses
- CWE-416
Description
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.
An attacker could leverage this vulnerability to execute code in the context of the current process.
Affected configurations
• siemens teamcenter visualization (>= 14.0.0 < 14.3.0.13)
• siemens teamcenter visualization (>= 2312.0 < 2312.0009)
• siemens teamcenter visualization (>= 2406.0 < 2406.0007)
• siemens teamcenter visualization (>= 2412.0 < 2412.0002)
• siemens tecnomatix plant simulation (>= 2302.0 < 2302.0021)
• siemens tecnomatix plant simulation (>= 2404.0 < 2404.0010)
Related
Weakness · CWE (1)
- CWE-416 Use After Free weakness
References
- https://cert-portal.siemens.com/productcert/html/ssa-050438.html Vendor Advisory