CVEvulnerability
CVE-2025-30042
9.0 CRITICAL
Official page ↗
- Status
- Analyzed
- Published
- 2026-03-02
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 4.0 ([email protected])
- 9.0 CRITICAL — CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- CVSS 3.1 ([email protected])
- 7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Weaknesses
- CWE-603
Description
The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.
Affected configurations
• cgm clininet (< 2025.ms2)
Related
Weakness · CWE (1)
- CWE-603 Use of Client-Side Authentication weakness
References
- https://cert.pl/en/posts/2026/03/CVE-2025-10350/ Third Party Advisory
- https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html Product