CVEvulnerability

CVE-2025-32841

8.7 HIGH Published 2025-04-16 Modified 2026-06-17 Official page ↗
Status
Analyzed
Published
2025-04-16
Last modified
2026-06-17
Assigner
[email protected]
CVSS 4.0 ([email protected])
8.7 HIGH — CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
8.8 HIGH — CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weaknesses
CWE-89

Description

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Affected configurations

• siemens telecontrol server basic (< 3.1.2.2)

Related

Weakness · CWE (1)

  • CWE-89 Improper Neutralization of Special Elements used in an SQL Command weakness

References