CVEvulnerability

CVE-2025-5022

6.5 MEDIUM Published 2025-07-10 Modified 2026-06-17 Official page ↗
Status
Deferred
Published
2025-07-10
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
6.5 MEDIUM — CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weaknesses
CWE-521

Description

Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020.

Related

Weakness · CWE (1)

  • CWE-521 Weak Password Requirements weakness

References