CVEvulnerability

CVE-2025-52586

7.5 HIGH Published 2025-08-08 Modified 2026-06-17 Official page ↗
Status
Deferred
Published
2025-08-08
Last modified
2026-06-17
Assigner
[email protected]
CVSS 4.0 ([email protected])
7.5 HIGH — CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
6.9 MEDIUM — CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L
Weaknesses
CWE-319

Description

The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.

Related

Weakness · CWE (1)

  • CWE-319 Cleartext Transmission of Sensitive Information weakness

References