CVEvulnerability
CVE-2025-59105
7.0 HIGH
Official page ↗
- Status
- Deferred
- Published
- 2026-01-26
- Last modified
- 2026-06-17
- Assigner
- 551230f0-3615-47bd-b7cc-93e92e730bbf
- CVSS 4.0 (551230f0-3615-47bd-b7cc-93e92e730bbf)
- 7.0 HIGH — CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Weaknesses
- CWE-312
Description
With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database.
Related
Weakness · CWE (1)
- CWE-312 Cleartext Storage of Sensitive Information weakness
References
- https://r.sec-consult.com/dkaccess r.sec-consult.com
- https://r.sec-consult.com/dormakaba r.sec-consult.com
- https://www.dormakabagroup.com/en/security-advisories www.dormakabagroup.com