CVEvulnerability

CVE-2025-63205

7.5 HIGH Published 2025-11-19 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2025-11-19
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 (134c704f-9b21-4f2e-91b3-4a467353bcc0)
7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weaknesses
CWE-200

Description

An issue was discovered in bridgetech probes VB220 IP Network Probe,VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD, firmware versions 6.5.0-9, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint. NOTE: the Supplier disagrees that 6.5.0-9 is affected, and instead reports that 5.6.0-3 and earlier are affected, and 5.6.0-4 (2020-09-21) and later are fixed.

Affected configurations

• bridgetech vb220 firmware 6.5.0-9 • bridgetech vb120 firmware 6.5.0-9 • bridgetech vb330 firmware 6.5.0-9 • bridgetech vb440 firmware 6.5.0-9 • bridgetech nomad portable firmware 6.5.0-9

Related

Weakness · CWE (1)

  • CWE-200 Exposure of Sensitive Information to an Unauthorized Actor weakness

References