CVEvulnerability

CVE-2025-66049

8.7 HIGH Published 2026-01-09 Modified 2026-06-17 Official page ↗
Status
Analyzed
Published
2026-01-09
Last modified
2026-06-17
Assigner
[email protected]
CVSS 4.0 ([email protected])
8.7 HIGH — CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weaknesses
CWE-306

Description

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

Affected configurations

• vivotek ip7137 firmware 0200a

Related

Weakness · CWE (1)

  • CWE-306 Missing Authentication for Critical Functionality weakness

References