CVEvulnerability
CVE-2026-12851
9.1 CRITICAL
Official page ↗
- Status
- Deferred
- Published
- 2026-06-24
- Last modified
- 2026-10-25
- Assigner
- 0df08a0e-a200-4957-9bb0-084f562506f9
- CVSS 3.1 (0df08a0e-a200-4957-9bb0-084f562506f9)
- 9.1 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
- Weaknesses
- CWE-78
Description
Multiple OS command injection vulnerabilities exist in the libNetSetObj.so functionality of GeoVision GV-I/O Box 4E 2.09. A specially crafted network packet can lead to command execution. An attacker can send a network request to trigger this vulnerability.
`libNetSetObj.so` is an internal library used by various binaries on the device to configure the network stack (start and stop various services, configure IP, Netmask, gateway, dns, etc.)
#### CNetSetObj::m_F_n_Set_DNS_Addr command injection
The following function can take up to two addresses, performs no sanitization and then calls `system`. This is a classic command injection vulnerability. The function is reachable from both the network-exposed `DVRSearch` service and the `Network.cgi` endpoint.
int __fastcall CNetSetObj::m_F_n_Set_DNS_Addr(CNetSetObj *this, char *dns1, char *dns2)
{
int result; // r0
char v5[80]; // [sp+0h] [bp-50h] BYREF
if ( !dns1 )
result = 0;
if ( dns1 )
{
sprintf(v5, "/bin/echo nameserver %s > /etc/resolv.conf", dns1); // attacker controlled dns1 field
system(v5);
if ( dns2 )
{
sprintf(v5, "/bin/echo nameserver %s >> /etc/resolv.conf", dns2);
system(v5);
}
return 1;
}
return result;
Related
Weakness · CWE (1)
- CWE-78 Improper Neutralization of Special Elements used in an OS Command weakness
References
- https://talosintelligence.com/vulnerability_reports/TALOS-2026-2379 talosintelligence.com
- https://www.geovision.com.tw/cyber_security.php www.geovision.com.tw