CVEvulnerability
CVE-2026-13381
8.7 HIGH
Official page ↗
- Status
- Analyzed
- Published
- 2026-07-20
- Last modified
- 2026-10-24
- Assigner
- 57dba5dd-1a03-47f6-8b36-e84e47d335d8
- CVSS 4.0 (57dba5dd-1a03-47f6-8b36-e84e47d335d8)
- 8.7 HIGH — CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- CVSS 3.1 ([email protected])
- 8.1 HIGH — CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
- Weaknesses
- CWE-639
Description
VSee Clinic 7.1.26 and API 1.3.0 contain an Insecure Direct Object Reference (IDOR) vulnerability in the /v1.3.0/api/files endpoint. An authenticated attacker can manipulate the 'remark' request parameter to enumerate, retrieve, and delete files belonging to other users on the application server.
Affected configurations
• vsee clinic 7.1.26
• vsee clinic api 1.3.0
Related
Weakness · CWE (1)
- CWE-639 Authorization Bypass Through User-Controlled Key weakness
References
- https://labs.sra.io/posts/vseeclinic Third Party Advisory
- https://vsee.com/clinic Product