CVEvulnerability

CVE-2026-1419

2.0 LOW Published 2026-01-26 Modified 2026-06-17 Official page ↗
Status
Analyzed
Published
2026-01-26
Last modified
2026-06-17
Assigner
[email protected]
CVSS 4.0 ([email protected])
2.0 LOW — CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
4.7 MEDIUM — CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
CVSS 3.1 ([email protected])
7.2 HIGH — CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
5.8 MEDIUM — AV:N/AC:L/Au:M/C:P/I:P/A:P
Weaknesses
CWE-74, CWE-77

Description

A weakness has been identified in D-Link DCS700l 1.03.09. Affected is an unknown function of the file /setDayNightMode of the component Web Form Handler. Executing a manipulation of the argument LightSensorControl can lead to command injection. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks.

Affected configurations

• dlink dcs-700l firmware 1.03.09

Related

Weakness · CWE (2)

  • CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component weakness
  • CWE-77 Improper Neutralization of Special Elements used in a Command weakness

References