CVEvulnerability
CVE-2026-16675
8.5 HIGH
Official page ↗
- Status
- Awaiting Analysis
- Published
- 2026-09-01
- Last modified
- 2026-09-01
- Assigner
- [email protected]
- CVSS 4.0 ([email protected])
- 8.5 HIGH — CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Weaknesses
- CWE-307
Description
A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.
Related
Weakness · CWE (1)
- CWE-307 Improper Restriction of Excessive Authentication Attempts weakness
References
- https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1799.html www.rockwellautomation.com