CVEvulnerability

CVE-2026-16933

8.2 HIGH Published 2026-08-19 Modified 2026-08-25 Official page ↗
Status
Analyzed
Published
2026-08-19
Last modified
2026-08-25
Assigner
[email protected]
CVSS 3.1 ([email protected])
8.2 HIGH — CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Weaknesses
CWE-190

Description

IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.

Affected configurations

• ibm power system s1122 \(9824-22a\) firmware (>= fw1110.00 < fw1110.31) • ibm power system s1122 \(9824-22a\) firmware fw1120.00 • ibm power system s1124 \(9824-42a\) firmware (>= fw1110.00 < fw1110.31) • ibm power system s1124 \(9824-42a\) firmware fw1120.00 • ibm power system s1122s \(9824-22b\) firmware (>= fw1110.00 < fw1110.31) • ibm power system s1122s \(9824-22b\) firmware fw1120.00 • ibm power system s1114 \(9824-41b\) firmware (>= fw1110.00 < fw1110.31) • ibm power system s1114 \(9824-41b\) firmware fw1120.00 • ibm power system l1122 \(9856-22h\) firmware (>= fw1110.00 < fw1110.31) • ibm power system l1122 \(9856-22h\) firmware fw1120.00 • ibm power system l1124 \(9856-42h\) firmware (>= fw1110.00 < fw1110.31) • ibm power system l1124 \(9856-42h\) firmware fw1120.00 • ibm power system e1150 \(9043-mru\) firmware (>= fw1110.00 < fw1110.31) • ibm power system e1150 \(9043-mru\) firmware fw1120.00 • ibm power system s1112 \(9242-21b\) firmware fw1120.00 • ibm power system s1112 \(9242-21t\) firmware fw1120.00 • ibm power system e1080 \(9080-hex\) firmware (>= fw1060.00 < fw1060.81) • ibm power system s1022 \(9105-22a\) firmware (>= fw1060.00 < fw1060.81) • ibm power system s1024 \(9105-42a\) firmware (>= fw1060.00 < fw1060.81) • ibm power system s1022s \(9105-22b\) firmware (>= fw1060.00 < fw1060.81) • ibm power system s1014 \(9105-41b\) firmware (>= fw1060.00 < fw1060.81) • ibm power system l1022 \(9786-22h\) firmware (>= fw1060.00 < fw1060.81) • ibm power system l1024 \(9786-42h\) firmware (>= fw1060.00 < fw1060.81) • ibm power system e1050 \(9043-mrx\) firmware (>= fw1060.00 < fw1060.81) • ibm power system s1012 \(9028-21b\) firmware (>= fw1060.00 < fw1060.81) • ibm power system e1180 \(9080-heu\) firmware (>= fw1110.00 < fw1110.31) • ibm power system e1180 \(9080-heu\) firmware fw1120.00 • ibm power system s922 \(9009-22g\) firmware (>= fw950.00 < fw950.h3) • ibm power system h922 \(9223-22s\) firmware (>= fw950.00 < fw950.h3) • ibm power system s914 \(9009-41g\) firmware (>= fw950.00 < fw950.h3) • ibm power system s924 \(9009-42g\) firmware (>= fw950.00 < fw950.h3) • ibm power system h924 \(9223-42s\) firmware (>= fw950.00 < fw950.h3) • ibm power system e950 \(9040-mr9\) firmware (>= fw950.00 < fw950.h3) • ibm power system e980 \(9080-m9s\) firmware (>= fw950.00 < fw950.h3) • ibm power system ac922 \(8335-gth\) firmware (>= op940 < op940.a2) • ibm power system ac922 \(8335-gtx\) firmware (>= op940 < op940.a2) • ibm power hardware management console \(7063-cr2\) firmware (>= op940 < op940.82)

Related

Weakness · CWE (1)

  • CWE-190 Integer Overflow or Wraparound weakness

References