IBM PowerVM Hypervisor FW1120.00 through FW1120.01, FW1110.00 through FW1110.31, and FW1060.00 through FW1060.81 is affected by a vulnerability in a hypervisor call interface. An attacker with root access to a guest partition can read a limited amount of hypervisor memory, potentially exposing sensitive data belonging to the hypervisor or other guest partitions hosted on the same system, resulting in a confidentiality impact. The attacker has no control over which memory contents are returned. This vulnerability is of particular concern in multi-tenant environments where guests may run arbitrary OS images.
Affected configurations
• ibm power system s1122 \(9824-22a\) firmware (>= fw1110.00 < fw1110.32)
• ibm power system s1122 \(9824-22a\) firmware (>= fw1120.00 < fw1120.02)
• ibm power system s1124 \(9824-42a\) firmware (>= fw1110.00 < fw1110.32)
• ibm power system s1124 \(9824-42a\) firmware (>= fw1120.00 < fw1120.02)
• ibm power system s1122s \(9824-22b\) firmware (>= fw1110.00 < fw1110.32)
• ibm power system s1122s \(9824-22b\) firmware (>= fw1120.00 < fw1120.02)
• ibm power system s1114 \(9824-41b\) firmware (>= fw1110.00 < fw1110.32)
• ibm power system s1114 \(9824-41b\) firmware (>= fw1120.00 < fw1120.02)
• ibm power system l1122 \(9856-22h\) firmware (>= fw1110.00 < fw1110.32)
• ibm power system l1122 \(9856-22h\) firmware (>= fw1120.00 < fw1120.02)
• ibm power system l1124 \(9856-42h\) firmware (>= fw1110.00 < fw1110.32)
• ibm power system l1124 \(9856-42h\) firmware (>= fw1120.00 < fw1120.02)
• ibm power system e1150 \(9043-mru\) firmware (>= fw1110.00 < fw1110.32)
• ibm power system e1150 \(9043-mru\) firmware (>= fw1120.00 < fw1120.02)
• ibm power system s1112 \(9242-21b\) firmware (>= fw1120.00 < fw1120.02)
• ibm power system s1112 \(9242-21t\) firmware (>= fw1120.00 < fw1120.02)
• ibm power system e1080 \(9080-hex\) firmware (>= fw1060.00 < fw1060.82)
• ibm power system s1022 \(9105-22a\) firmware (>= fw1060.00 < fw1060.82)
• ibm power system s1024 \(9105-42a\) firmware (>= fw1060.00 < fw1060.82)
• ibm power system s1022s \(9105-22b\) firmware (>= fw1060.00 < fw1060.82)
• ibm power system s1014 \(9105-41b\) firmware (>= fw1060.00 < fw1060.82)
• ibm power system l1022 \(9786-22h\) firmware (>= fw1060.00 < fw1060.82)
• ibm power system l1024 \(9786-42h\) firmware (>= fw1060.00 < fw1060.82)
• ibm power system e1050 \(9043-mrx\) firmware (>= fw1060.00 < fw1060.82)
• ibm power system s1012 \(9028-21b\) firmware (>= fw1060.00 < fw1060.82)
• ibm power system e1180 \(9080-heu\) firmware (>= fw1110.00 < fw1110.32)
• ibm power system e1180 \(9080-heu\) firmware (>= fw1120.00 < fw1120.02)
Related
Weakness · CWE (1)
- CWE-457 Use of Uninitialized Variable weakness
References
- https://www.ibm.com/support/pages/node/7289137 Patch, Vendor Advisory