CVEvulnerability

CVE-2026-25599

6.3 MEDIUM Published 2026-06-01 Modified 2026-07-22 Official page ↗
Status
Awaiting Analysis
Published
2026-06-01
Last modified
2026-07-22
Assigner
a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
CVSS 3.1 (a6d3dc9e-0591-4a13-bce7-0f5b31ff6158)
6.3 MEDIUM — CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L
Weaknesses
CWE-306, CWE-319, CWE-79

Description

Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.

Related

Weakness · CWE (3)

  • CWE-306 Missing Authentication for Critical Functionality weakness
  • CWE-319 Cleartext Transmission of Sensitive Information weakness
  • CWE-79 Improper Neutralization of Input During Web Page Generation weakness