CVEvulnerability

CVE-2026-25787

9.3 CRITICAL Published 2026-05-12 Modified 2026-07-14 Official page ↗
Status
Awaiting Analysis
Published
2026-05-12
Last modified
2026-07-14
Assigner
[email protected]
CVSS 4.0 ([email protected])
9.3 CRITICAL — CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
9.1 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Weaknesses
CWE-79

Description

Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "Motion Control Diagnostics" parameters page, the malicious code would be executed in the scope of their web session.

Related

Weakness · CWE (1)

  • CWE-79 Improper Neutralization of Input During Web Page Generation weakness

References