CVE-2026-35226

7.1 HIGH Published 2026-07-29 Modified 2026-10-23 Official page ↗
Status
Deferred
Published
2026-07-29
Last modified
2026-10-23
Assigner
[email protected]
CVSS 4.0 ([email protected])
7.1 HIGH — CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
6.5 MEDIUM — CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weaknesses
CWE-787

Description

An out‑of‑bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and results in a controlled stop of the PLC application.

Related

Weakness · CWE (1)

  • CWE-787 Out-of-bounds Write weakness