CVEvulnerability
CVE-2026-42808
6.8 MEDIUM
Official page ↗
- Status
- Awaiting Analysis
- Published
- 2026-09-10
- Last modified
- 2026-09-10
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 6.8 MEDIUM — CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Weaknesses
- CWE-120
Description
An issue was discovered in Bosch Sensortec COINES_SDK versions 2.0 through 2.11.
The host streaming API function {{coines_read_stream_sensor_data()}} fails to validate the boundaries of the caller-provided destination buffer.
Internally, the stream processing mechanism in {{comm_intf_process_stream_response()}} discards the requested {{number_of_samples}} argument and copies the entirety of the streaming ring buffer's accumulated data into {{coines_stream_rsp_buf}}.
Subsequently, {{coines_read_stream_sensor_data()}} unconditionally executes a {{memcpy}} of the ring buffer size into the caller-provided buffer without verifying if the destination memory allocation is large enough.
A malicious or compromised hardware board connected via USB or BLE can exploit this by streaming a high volume of sensor samples, causing a heap or stack-based buffer overflow on the host desktop environment.
This can result in a Denial of Service (DoS) or potential arbitrary code execution on the host machine.
Related
Weakness · CWE (1)
- CWE-120 Buffer Copy without Checking Size of Input weakness
References
- https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html psirt.bosch.com