CVEvulnerability

CVE-2026-43275

4.7 MEDIUM Published 2026-05-06 Modified 2026-06-17 Official page ↗
Status
Analyzed
Published
2026-05-06
Last modified
2026-06-17
Assigner
416baaa9-dc9f-4396-8d5f-8c081fb06d67
CVSS 3.1 ([email protected])
4.7 MEDIUM — CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H
Weaknesses
CWE-362

Description

In the Linux kernel, the following vulnerability has been resolved: scsi: ufs: core: Flush exception handling work when RPM level is zero Ensure that the exception event handling work is explicitly flushed during suspend when the runtime power management level is set to UFS_PM_LVL_0. When the RPM level is zero, the device power mode and link state both remain active. Previously, the UFS core driver bypassed flushing exception event handling jobs in this configuration. This created a race condition where the driver could attempt to access the host controller to handle an exception after the system had already entered a deep power-down state, resulting in a system crash. Explicitly flush this work and disable auto BKOPs before the suspend callback proceeds. This guarantees that pending exception tasks complete and prevents illegal hardware access during the power-down sequence.

Affected configurations

• linux linux kernel (>= 3.18 < 5.15.202) • linux linux kernel (>= 5.16 < 6.1.165) • linux linux kernel (>= 6.2 < 6.6.128) • linux linux kernel (>= 6.7 < 6.12.75) • linux linux kernel (>= 6.13 < 6.18.16) • linux linux kernel (>= 6.19 < 6.19.6)

Related

Weakness · CWE (1)

  • CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization weakness

References