CVEvulnerability
CVE-2026-46749
5.0 MEDIUM
Official page ↗
- Status
- Analyzed
- Published
- 2026-06-09
- Last modified
- 2026-10-23
- Assigner
- [email protected]
- CVSS 4.0 ([email protected])
- 5.0 MEDIUM — CVSS:4.0/AV:L/AC:H/AT:P/PR:H/UI:N/VC:L/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- CVSS 3.1 ([email protected])
- 7.5 HIGH — CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H
- CVSS 3.1 ([email protected])
- 9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Weaknesses
- CWE-760
Description
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access.
Affected configurations
• siemens sinec ins (<= 1.0)
• siemens sinec ins 1.0
Related
Weakness · CWE (1)
- CWE-760 Use of a One-Way Hash with a Predictable Salt weakness
References
- https://cert-portal.siemens.com/productcert/html/ssa-860189.html Vendor Advisory