CVEvulnerability

CVE-2026-9143

6.3 MEDIUM Published 2026-06-19 Modified 2026-06-25 Official page ↗
Status
Analyzed
Published
2026-06-19
Last modified
2026-06-25
Assigner
[email protected]
CVSS 4.0 ([email protected])
6.3 MEDIUM — CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
3.7 LOW — CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N
CVSS 3.1 ([email protected])
5.3 MEDIUM — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
Weaknesses
CWE-681

Description

There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen.  This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and prior versions.

Affected configurations

• ni instrumentstudio (<= 2025) • ni instrumentstudio 2026 • ni ni grpc device server (< 2.18.0)

Related

Weakness · CWE (1)

  • CWE-681 Incorrect Conversion between Numeric Types weakness

References