GitHub Advisoryadvisory · Maven
GHSA-fx9p-2qvx-pgjv Jenkins ElectricFlow Plugin is vulnerable to stored cross site scripting vulnerability
MEDIUM
Official page ↗
- Aliases
- CVE-2019-10335
- Ecosystem
- Maven
- Packages
- org.jenkins-ci.plugins:electricflow
- Severity
- Moderate
- CVSS vector
- CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
- Weaknesses
- CWE-79
- Reviewed
- 2023-10-26
Affected packages
• Maven org.jenkins-ci.plugins:electricflow: < 1.1.7 → fixed in 1.1.7
Description
The plugin adds metadata displayed on build pages during its operations.
Any user content was not escaped, resulting in a cross-site scripting vulnerability allowing users with Job/Configure permission, or attackers controlling API responses received from ElectricFlow to render arbitrary HTML and JavaScript on Jenkins build pages.
Build metadata is now filtered through a HTML formatter that only allows showing basic HTML, neutralizing any unsafe data. Additionally, all builds executed after the security update is applied will now properly escape content received from ElectricFlow.
Related
Alias · CVE (1)
- CVE-2019-10335 A stored cross site scripting vulnerability in Jenkins ElectricFlow Plugin 1.1.5 and earlier allowed attackers able to configure jobs in… vulnerability
Weakness · CWE (1)
- CWE-79 Improper Neutralization of Input During Web Page Generation weakness
References
- https://nvd.nist.gov/vuln/detail/CVE-2019-10335 advisory
- https://github.com/jenkinsci/electricflow-plugin/commit/1a90ee7727f8c6925df3e410837ddf6be28cce53 web
- https://jenkins.io/security/advisory/2019-06-11/#SECURITY-1412 web
- https://web.archive.org/web/20200227033720/http://www.securityfocus.com/bid/108747 web
- http://www.openwall.com/lists/oss-security/2019/06/11/1 web