ComplianceNIST 800-53 enhancement
NIST-AU-5(4) Shutdown on Failure
- Framework
- NIST SP 800-53 rev5 (5.2.0)
- Family
- AU Audit and Accountability
- Control
- AU-5(4)
Control statement
Invoke a [Selection (one or more of): full system shutdown; partial system shutdown; degraded operational mode with limited mission or business functionality available] in the event of [Assignment: audit logging failures] , unless an alternate audit logging capability exists.
Discussion
Organizations determine the types of audit logging failures that can trigger automatic system shutdowns or degraded operations. Because of the importance of ensuring mission and business continuity, organizations may determine that the nature of the audit logging failure is not so severe that it warrants a complete shutdown of the system supporting the core organizational mission and business functions. In those instances, partial system shutdowns or operating in a degraded mode with reduced capability may be viable alternatives.
Related
Related control · not in database (1)
Enhancement of · Compliance (1)
- NIST-AU-5 Response to Audit Logging Process Failures NIST 800-53 control