CVEvulnerability

CVE-2018-11447

8.8 HIGH Published 2018-06-26 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2018-06-26
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
8.8 HIGH — CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
6.8 MEDIUM — AV:N/AC:M/Au:N/C:P/I:P/A:P
Weaknesses
CWE-121, CWE-352

Description

A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.

Affected configurations

• siemens scalance m875 firmware

Related

Weakness · CWE (2)

  • CWE-121 Stack-based Buffer Overflow weakness
  • CWE-352 Cross-Site Request Forgery weakness

References