CVEvulnerability
CVE-2024-39512
7.0 HIGH
Official page ↗
- Status
- Analyzed
- Published
- 2024-07-10
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 4.0 ([email protected])
- 7.0 HIGH — CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- CVSS 3.1 ([email protected])
- 6.6 MEDIUM — CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Weaknesses
- CWE-1263
Description
An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get access to a user account.
When the console cable is disconnected, the logged in user is not logged out. This allows a malicious attacker with physical access to the console to resume a previous session and possibly gain administrative privileges.
This issue affects Junos OS Evolved:
* from 23.2R2-EVO before 23.2R2-S1-EVO,
* from 23.4R1-EVO before 23.4R2-EVO.
Affected configurations
• juniper junos os evolved 23.2
• juniper junos os evolved 23.4
Related
Weakness · CWE (1)
- CWE-1263 Improper Physical Access Control weakness
References
- https://supportportal.juniper.net/JSA82977 Vendor Advisory
- https://supportportal.juniper.net/JSA82977 Vendor Advisory