CVEvulnerability

CVE-2025-14095

6.8 MEDIUM Published 2025-12-17 Modified 2026-10-07 Official page ↗
Status
Deferred
Published
2025-12-17
Last modified
2026-10-07
Assigner
46b595e9-1acc-41cb-9398-adaf98d37a9b
CVSS 3.1 (46b595e9-1acc-41cb-9398-adaf98d37a9b)
6.8 MEDIUM — CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weaknesses
CWE-284, CWE-693

Description

A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software.  Other related CVE's are CVE-2025-14096 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required configuration for Exposure: Physical access to the analyzer is needed. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication.                                                                                                                                                                                        Note: CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems.

Related

Weakness · CWE (2)

  • CWE-284 Improper Access Control weakness
  • CWE-693 Protection Mechanism Failure weakness

References