CVEvulnerability

CVE-2025-5023

7.1 HIGH Published 2025-07-10 Modified 2026-06-17 Official page ↗
Status
Deferred
Published
2025-07-10
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
7.1 HIGH — CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H
Weaknesses
CWE-798

Description

Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020.

Related

Weakness · CWE (1)

  • CWE-798 Use of Hard-coded Credentials weakness

References